Mechanical ventilation is necessary and used in many areas of patient care. STPL offers INDOVENT, a dual solution ventilator which combines the advantages of a flexible non-invasive ventilator with a full-featured invasive ventilator for all patient groups in the intensive care unit, emergency ward, recovery room or intermediate care as well as in long-term acute care facilities and during intra-hospital transport.
Requiring a minimum space, the INDOVENT provides mechanical breathing support with maximum mobility. It is coupled with high-capacity batteries to ventilate the patients during intra-hospital transport without the need for an external power source.
Ventilation Modes:
• VCV - Volume Controlled Ventilation
• PSV - Pressure Support Ventilation
• ACV - Assist-Control Ventilation
Superior Mobile ventilator:
• Compact, big capacity battery, no air compressor, intra-hospital mobility
• Flexible device configuration: mount on a trolley, bed or ceiling pendant
• Compatible with automotive charging stations.
Engineered for reliability
• Rugged and Robust design
• Very compact footprint
Optimal patient-ventilator synchrony, increase patient comfort
• The Electronically Controlled Tidal Volume System - Keep precise control on the tidal volume of each breath delivered to the patient by adjusting compensation dosage automatically
• Auto Calibration - Enhance sensitivity, avoid spurious triggering.
• Electronically controlled Inspiration-Expiration ratio(IE).
Safe Ventilation Through Whole Treatment Phase
• Non-invasive ventilation mode associated with decreased intubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection
Operating Specifications | |
---|---|
Suitability for patient types | Adult |
Operation type | Automatic electromechanical compression of AMBU Bag |
Control modes | VCV, PSV & ACV |
AMBU Bag size | Adult (1500 - 1600 ml) |
Max respiratory flow rate | 20 liters per minute |
Tidal Volume | Range : 100 - 600 ml. Can be adjusted electronically in step size of 50 ml |
I:E Ratio | Range : 1:1 to 1:5. Can be adjusted electronically in step size of 1 |
Peak Inspiratory pressure limit | 0-50 cm H2O; Can be adjusted electronically in step size of 1 |
PEEP function | PEEP valve of 5-20 cm of H2O |
Reusability of AMBU Bag | Yes |
Inline HEPA filter | Yes |
Machine operation failure | Yes |
Electrical and Mechanical Specifications | |
---|---|
Power supply requirement | 230 V AC (50/60 Hz) or Automotive charger plug with adequate current capacity |
Backup battery | Sealed automotive battery. To be purchased separately |
Battery backup | 5 to 6 hours on a fully charged battery |
Power Consumption | 125 Watts (Approx.) |
Motor life | 2 years (Approx.) |
Dimension | 228 mm x 320 mm x 275 mm (L x W x H) |
Weight | 9.5 Kg (8.5 Kg without battery) |
Alarms |
Power disconnected |
Machine operation failure |
High inspiratory pressure |
User Interface | |
---|---|
User interface | Four analogue rotary dials for command inputs. Two line backlit LCD display for inputs commands and parameters display. |
Input order Control | Five analogue rotary dials 1. Tidal Volume 2. Respiratory Rate 3. Inspiration:Expiration time ratio 4. Alarm pressure setting 5. Mode control |
Display | Two line LCD readout of set parameters and Air volume per minute display |
Alarm | Buzzer |
Warranty | |
---|---|
One year warranty for manufacturing defects from the date of shipment.* |